In many electronic systems, power must be transferred between circuits that cannot share the same electrical ground. Direct electrical connection between input and output can create problems such as ground loops, electrical noise transfer, and safety risks, especially in high-voltage or long cable systems. Sensitive electronics can be damaged by voltage spikes or fault conditions if proper isolation is not maintained. An isolated DC-DC converter solves this by transferring power without creating a direct electrical connection between input and output sides.
| Image | Part Number / Manufacturer | Description / Specs | MOQ | Datasheet | RFQ | |
|---|---|---|---|---|---|---|
![]() | 160M14-660 Manufacturer: Eaton - Bussmann Electrical Division Category: Electrical RoHSREACH | FUSE CRTRDGE 160A 660VAC/400VDC | 1 | |||
![]() | 125M14-660 Manufacturer: Eaton - Bussmann Electrical Division Category: Electrical RoHSREACH | FUSE CRTRDGE 125A 690VAC/400VDC | 1 | |||
| RES-5 Manufacturer: Eaton - Bussmann Electrical Division Category: Electrical RoHSREACH | FUSE SUPER LAG RENEW. 5/600 | 1 | ||||
| RES-3 Manufacturer: Eaton - Bussmann Electrical Division Category: Electrical RoHSREACH | FUSE SUPER LAG RENEW. 3/600 | 1 | ||||
| 0RLS060.T Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 60A 600VAC | 1 | ||||
| LA50QS404 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 40A 500VAC/VDC | 1 | ||||
| EV1K060.ZXBD Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 60A 1 KVDC CYL | 1 | ||||
| EV1K070 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 70A 1 KVDC CYL | 1 | ||||
| MIC-20 Manufacturer: Eaton - Bussmann Electrical Division Category: Electrical RoHSREACH | BUSS MIDGET FUSE INDICATING | 1 | ||||
| LA50QS354 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 35A 500VAC/VDC | 1 | ||||
| LA50QS504 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 50A 500VAC/VDC | 1 | ||||
| EV1K090 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 90A 1 KVDC CYL | 1 | ||||
| LA50QS151 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 15A 500VAC/VDC | 1 | ||||
| LA50QS301 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 30A 500VAC/VDC | 1 | ||||
| LA50QS251 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 25A 500VAC/VDC | 1 | ||||
| LA50QS101 Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 10A 500VAC/VDC | 1 | ||||
![]() | DD200 Manufacturer: Eaton - Bussmann Electrical Division Category: Electrical RoHSREACH | FUSE CRTRDGE 200A 415VAC CYLINDR | 1 | |||
![]() | 80L14-660 Manufacturer: Eaton - Bussmann Electrical Division Category: Electrical RoHSREACH | FUSE CARTRIDGE 80A 660VAC/400VDC | 1 | |||
![]() | C22M125 Manufacturer: Eaton - Bussmann Electrical Division Category: Electrical RoHSREACH | FUSE CARTRIDGE 125A 400VAC | 1 | |||
| 0RLS012.T Manufacturer: Littelfuse Inc. Category: Electrical RoHSREACH | FUSE CARTRIDGE 12A 600VAC | 1 |
Isolated DC-DC converters are usually selected early in power architecture design and matched to isolation voltage rating, load conditions, and thermal limits. When an isolated converter reaches end-of-life, replacement can be difficult. Differences in isolation rating, transformer design, switching behavior, or pin layout can affect safety compliance and system stability.
This is common in industrial, medical, and telecom equipment where systems operate for many years. Maintenance teams often require the same converter to avoid redesign, safety recertification, or compliance testing. Delays in sourcing compatible isolated converters can increase downtime and maintenance cost.
Maketronics supports global engineering and procurement teams with reliable sourcing of both active and obsolete Isolated DC-DC Converters.
It transfers power between circuits while maintaining electrical isolation, improving safety and noise immunity.
Isolation protects equipment and users by preventing voltage faults, ground loops, and electrical noise from propagating between circuits.
They may have slightly lower efficiency due to the isolation stage, but they provide critical safety, noise protection, and system reliability benefits.
Isolation voltage rating, safety compliance, transformer design, switching behavior, and pin compatibility must be verified to maintain system safety and performance.